Product Description
Product Description:
new technology product in china
This kind of solar inverter upgraded and promote completely according to the
advantages and disadvantages of old one,use latest power efficiency technology.
with high conversion efficiency,stable performance,low no load consumption,
strong overload capacity,strong antijamming capability;supply pure sine wave AC
power for commercial,industry,communication,civilian,army.
It is suitable for DC12V 24V 48V 72V Solar power system,power air condition,TV
set,cash register,fridge,washing machine,computer,electrical tool,lighting,industry
equipment,communication equipments etc.
Product Features:
1.Pure sine wave output.Built-in transfer switch automatically transfers between inverter power and incoming AC power
2.CPU management,intelligent control,module design
3.LED/LCD display function
4.High conversion efficiency (between 90%-98%),low consumption
5.Can match with various battery types,
such as sealed lead acid battery,open lead acid battery,gel battery and different
types of lithium batteries.Three-step intelligent charging mode available.
-Able to charge various types of battery
-Maximum charging current is adjustable
-Can be use as a charger
6.Also called a dynamic inverter,due to the advantage of having a powerful
overload capacity. For example,1KW model can power 1P air conditioning.2KW
can power 2Ps of air conditioning,3KW can power 3Ps of air conditioning,etc.
7.With adopting the latest American low frequency circuit design and new electric
materials, the whole system is more stable,with a low malfunction rate and long-life.Under normal usage,product life expectancy is 8 years.
8.Protection: High voltage protection
Under-voltage protection
Over-temperature shutdown
Automatic overload protection
Short-circuit protection
9.Power efficiency designing,resisting harmonic wave and inductive load ,safe
and stable.
10.The frequency of 50/60HZ automatic selection,give priority to use AC and DC
with automatic adjustment.display dynamic schematic diagram,comprehensive
functions.easier to use.
11.Pure copper transformer , blind post and wire.High density conformal coating.
Double ball bearing mute dc fan,Large LCD screen,Large current terminals,Best
electric components,best packing,safe,efficient and high level.
(postscript:DC36V and any other would be customized.)
Parameters of Solar off grid Inverter
Solar inverter parameters specifications |
Power Specifications | 300W~12KW |
DC Input Specifications |
Rated Voltage Specifications | DC12/24/48/72V-AC220V | DC12/24/48/72V-AC110V |
Operating Voltage Range(Normal Operating Battery Voltage) | 10V-16V (DC12V) 20V-32V (DC24V) 40V-64V (DC48V) 60V-96V (DC72V) |
Low Voltage Alarm(alarm to alert users when battery's voltage is over low) | 10.5Vdc ± 0.3Vdc (12V) 21.0Vdc ± 0.6Vdc (24V) 42.0Vdc ± 1.2Vdc (48V) 63.0vdc ± 1.8Vdc (72V) |
Low Voltage Shut off (shut off when battery's voltage is over low) | 10.0Vdc ± 0.3Vdc (12V) 20.0Vdc ± 0.6Vdc (24V) 40.0Vdc ± 1.2Vdc (48V) 60.0Vdc ± 1.8Vdc (72V) |
Low Voltage Recovery (Automatic Boot when battery's voltage returns to normal) | 12.0Vdc ± 0.3Vdc (12V) 24.0Vdc ± 0.3Vdc (24V) 48.0Vdc ± 0.3Vdc (48V) 72.0Vdc ± 0.3Vdc (72V) |
High Voltage Alarm and shut off ( alarms and shut off when the battery's voltage is over high) | 16Vdc ± 0.3Vdc (12V) 32Vdc ± 0.6Vdc (24V) 64Vdc ± 1.2Vdc (48V) 96Vdc ± 1.8Vdc (72V) |
High Voltage Recovery (Automatic boot when battery's voltage returns to normal) | 15.5Vdc ± 0.3Vdc (12V) 31.0Vdc ± 0.6Vdc (24V) 62.0Vdc ± 1.2Vdc (48V) 93.0Vdc ± 1.8Vdc (72V) |
Inverter Efficiency | ≥90% |
DC-priority type, battery low voltage conversion point when there is utility electricity bypass ( battery voltage is lower than this, turn to utility electricity to supply) | 11Vdc ± 0.3Vdc (12V) 22Vdc ± 0.6Vdc (24V) 44Vdc ± 1.2Vdc (48V) 66Vdc ± 1.8Vdc (72V) |
DC-priority type, after turning to utility electricity to supply, the battery low voltage recovery point (when the battery's voltage is higher than this, turn to battery to supply electricity) | 13.5Vdc ± 0.3Vdc (12V) 27.0Vdc ± 0.6Vdc (24V) 54.0Vdc ± 1.2Vdc (48V) 81.0Vdc ± 1.8Vdc (72V) |
AC Input Specifications |
Rated Voltage Specifications | 220VAC System | 110VAC System |
Input Voltage Waveform | Sine wave (utility electricity or generator) | Sine wave (utility electricity or generator) |
Rated Input Voltage | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac |
Low Voltage Shut off | 180Vac±4% | 85Vac±4% |
Low Voltage Recovery | 195Vac ±4% | 90Vac ±4% |
High Voltage Shut off | 260Vac±4% | 135Vac±4% |
High Voltage Recovery | 255Vac±4% | 130Vac±4% |
Utility Electricity Charging rule | Three Stages: |
Constant current charging (constant stage)→constant voltage(constant voltage stage)→float (constant voltage stage) |
Utility Electricity Supply Efficiency | ≥98% |
Conversion Time (AC to DC) | <4ms |
Conversion Time (DC to AC) | <8ms |
AC output specifications |
Rated output voltage (V) | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac |
Output Voltage Range | ±10% rms |
Rated output frequency(Hz) | 50Hz ± 0.3Hz/60Hz ± 0.3Hz(Optional) |
Power Factor | 1.0 |
Output Waveform | Pure sine wave |
Waveform distortion rate( THD ) | ≤3% ( Linear load ) |
Dynamic Response( 0~100% ) | 5% |
Peak Factor ( CF ) | 3:1 |
Overload Protection (SMPS load) | (110%<Load<125%) ±10% :after 15 minutes disconnecting the output voltage (125%<Load<150%) ±10% :after 1 minute disconnecting the output voltage (Load>150%) ±10% :after 20 seconds disconnecting the output voltage |
Other notes |
Continuous operation time | Continuous operation |
Normal Boot no-load Depletion | ≤Rated Power×2.5% |
No-load Depletion of energy-saving mode | ≤6W |
Safety Certification | CE(EN62040-1) EMC :EN62040-2, C2 |
Communication Interface | RS232 / (Customizable) |
Cooling | Temperature-controlled variable speed fan cooling (Ventilation condition) |
Noise( dB,1 meter ) | <60dB |
Ambient temperature ( ºC ) | -10~+45 |
Storage Temperature( ºC ) | -20~+55 |
Using Environment Humidity | 0-95% relative humidity(No condensation) |
Altitude( m ) | ≤5000( More than 1000 m, derating ) |
Display Way | LED Indicator +LCD Display |
Alarm Way | Buzzer sounds alarm |
Protection Functions | Low voltage protection, high voltage protection, high temperature protection, short circuit protection, leakage protection, overcurrent protection, overload protection, low recovery, high recovery, intelligent temperature control, solid barrier alarm |
Protection Level | IP20 / Customizable |
Choosing the right inverter?
First step is to establish the power required to run your equipment. Most appliances/ tools
have their wattage stamped on the nameplate or listed in the owner's manual. Simply add your
appliance wattages together to arrive at a total figure. If you find you can only local the amps,
use this simple calculation:240volts* Amps =Watts.
Step two is selecting the correct size inverter. Resistive load(lights, chargers, etc.) only
require yourinverters rated output. Inductive loads such as an air conditioner,refrigerator/f
reezer requires 5,7 times the continuous rating, e.g. an 80w refrigerator requires a 600w
inverter. Power tools, fluorescent lights, TV also requires 3,4 times more wattage at start up.
Therefore you would need a 1000W inverter to power a 250W drill.
Keep in mind, it's an inverter, not a power station, choosing an inverter with 25-30% above
your needs is recommended. If you're unsure of your requirements, ask us or a licensed
electrician.
FAQ
Q 1.Why do you choose us?
A. We are a professional manufacturer specializing in solar products, such as
solar inverter, pure sine wave inverter, solar controller etc. We use the new 100%
pure copper transformer material for inverter, so our inverters have high
overload ability, high efficiency convertion (90%-98%), stable and many
protection( low voltage protection, high voltage protection, high temperature
protection, short circuit protection, leakage protection, overcurrent protection,
overload protection, low voltage recovery, high voltage recovery, intelligent
temperature control, solid barrier alarm).
Q 2. What's the payment terms?
A. T/T or Paypal
Q 3. How's the delivery time?
A. It takes 1-3 days for sample order after your payment, also according to your order quantity.
Q 4. How's the standard of package?
A. Use strong wooden case for protection, also can according to your requirement.
Q 5. What kind of material of transformer?
A. We use the new 100% pure copper transformer, which made the inverter has
high efficiency convertion, stable, high quality etc.
Q 6. What's the difference between 12, 24, and 48 volt inverters?
A. This refers to the input voltage from the battery bank. The main consideration
is that at higher voltages the current is less so that you can use smaller wires
between your solar panel array and your battery bank. Of course, when you
decide on a system voltage, the Solar Panels, Inverter, and Battery Bank all need
to use the same voltage.
Q 7. What kind of certificate you have?
A. Our company has already achieved CE, EMC certification.