1. INV-A1 Solar inverter introduction:
This kind of solar inverter upgraded and promote completely according to the adavantages and disadvantages of old one, use latest power efficiency technology.
With high convert efficiency, stable performance, low no load consumption, strong overload capacity, strong anti-jamming capability; Supply pure sine wave AC power for commercial, industry, communication, civilian, army.
It is suitable for DC12V 24V 48V 72V Solar power system, power air condition, TV set, cash register, fridge,
Washing machine, computer, electrical tool, lighting, industry equipment, communication equipment. Etc.
2. Description of the diagram
A, Give priority to the use of AC
Step1: When commercial power input is normal, AC power the load directly and recharge battery.
Step2: When commercial power shut off, the system will switch to give priority to the use of DC in 5ms automatically, ensuring normal working.
Step3: When commercial power is recovery, system will switch to give priority to use of AC and recharge battery.
B, Give priority to the use of DC
Recharge battery mainly from solar energy, commercial power assist recharging.
Step1: When commercial power is normal, voltage of battery higher than 11V, DC turn into AC through inverter and power load.
Step2: When the voltage of battery is lower than 11V, the system switch to commercial power automatically and recharging battery.
Step3: When the voltage of battery up to 13.5V, system switch to photovoltaic power and power the load.
Step4: When both commercial power and photovoltaic power broke down, battey will shut off with voltage lower than 10v
If commercial power is normal, AC will power load and recharge battery.
If commercial power still broke down, photovoltaic power recharge battery until voltage up to 12v and turn on with conversion mode.
3. Characters
1. Pure sine wave output. Built-in transfer switch automatically transfers between inverter power and incoming AC power
2. CPU management, intelligent control, module design
3. LED/LCD display function
4. High conversion efficiency (between 90%-98%), low consumption(1-6W)
5. Can match with various battery types, such as sealed lead acid battery, open lead acid battery, gel battery and different types of lithium batteries.
Three-step intelligent charging mode available.
-Able to charge various types of battery
-Maximum charging current is adjustable
-Can be use as a charger
7. Also called a dynamic inverter, due to the advantage of having a powerful overload capacity. For example, 1KW model can power 1P air conditioning. 2KW can power 2Ps of air conditioning, 3KW can power 3Ps of air conditioning, etc.
8. With adopting the latest American low frequency circuit design and new electric materials, the whole system is more stable, with a low malfunction rate and long-life. Under normal usage, product life expectancy is 8 years.
9. Protection: High voltage protection
Under-voltage protection
Over-temperature shutdown
Automatic overload protection
Short-circuit protection
10. Power efficiency designing, resisting harmonic wave and inductive load, safe and stable.
11. The frequency of 50/60HZ automatic selection, give priority to use AC and DC with automatic adjustment. Display dynamic schematic diagram, comprehensive functions. Easier to use.
12. Pure copper transformer, blind post and wire. High density conformal coating. Double ball bearing mute dc fan, Large LCD screen, Large current terminals, Best electric components, best packing, safe, efficient and high level.
Model | 1000W-6000W |
DC Input | 1KW-3KW: DC12V & DC24V& DC48V(Select one) 4KW-6KW: DC24V & DC48V(Select one) |
AC ouput | AC220V & AC110V & AC100V & AC230V & AC240V (Select one) |
Nominal Output Frequency (Hz) | 50HZ & 60HZ(Automatic selection) |
UPS function | Yes (Can give up the use ) |
AC charging function | Yes (Can give up the use ) |
Utility Model Specifications |
| AC220V | AC110V |
Efficiency | ≥ 98% |
Input Wave Type | Pure sine wave (utility or generator) | Pure sine wave (utility or generator) |
Input Voltage Range | AC 154V~AC263V | AC 77V~132V |
Nominal Input Voltage | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac |
Low Voltage shutoff | 154Vac± 4% | 77Vac± 4% |
Low Voltage Recovery | 164Vac ± 4% | 82Vac ± 4% |
Over voltage Shut off | 263Vac± 4% | 132Vac± 4% |
Over Voltage Recovery | 253Vac± 4% | 127Vac± 4% |
Nominal Input Frequency | 50Hz/ 60Hz (auto detect) | 50Hz/ 60Hz (auto detect) |
Output Wave Type | Same as the input wave type | Same as the input wave type |
Transfer Time (Ac to Dc) | < 10ms | < 10ms |
Transfer Time (Dc to Ac) | < 5ms | < 5ms |
Inverter Mode Specification |
Power Factor | 1 (Sufficient output power) |
Rated Output Voltage (V) | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac |
Nominal Output Frequency (Hz) | 50/60 ± 0.3Hz (auto detect) |
Output Voltage Range | ± 10% rms |
Efficiency | > 88% (DC12V: > 88%, DC24V: > 90%, DC48V: > 94%) |
Over-Load Protection | (110%< load< 125%) ± 10%: Fault (shutdown output) after 15 minutes; |
(125%< load< 150%) ± 10%: Fault (shutdown output) after 10s; |
Load> 150% ± 10%: Fault (shutdown output) after 20s; |
Low Battery Alarm | 10.5Vdc ± 0.3Vdc (If 12V Input) |
21.0Vdc ± 0.6Vdc (If 24V Input) |
42.0Vdc ± 0.6Vdc (If 48V Input) |
Low DC input voltage automatic shut-down | 10.0Vdc ± 0.3Vdc(If 12V Input) |
20.0vdc± 0.6Vdc (If 24V Input) |
40.0vdc± 0.6Vdc (If 48V Input) |
High DC input voltage warning & outage | 16Vdc ± 0.3Vdc (If 12V Input) |
32Vdc ± 0.6Vdc (If 24V Input) |
64Vdc ± 0.6Vdc (If 48V Input) |
High DC input voltage Recover | 15.5Vdc ± 0.3Vdc(If 12V Input) |
31.0Vdc ± 0.6Vdc (If 24V Input) |
62.0Vdc ± 0.6Vdc (If 48V Input) |
Power-saving mode | < 10W |
Power on mode | 20W~60W |
Safety | CE, EMC, LVD, SGS, ISO9001 |
Communication port | RS232 |
Cooling | Cooling-Variable Speed Fan run under ventilation condition. |
Operating Temperature Range | 0° Cto 60° C |
Storage temperature | -15º C~60º C |
humidity | 5% to 95% |
Noise | Max 60dB |
Detailed parameters of electrified wire netting to battery charging |
Model | Specification | 1012 | 1024 | 2012 | 2024 | 3012 | 3024 | 3048 | 4024 | 4048 | 5024 | 5048 | 6024 | 6048 | Input voltage | 110Vac/120Vac/220Vac/230Vac | Input voltage range | 88~127Vac/165~255Vac | Output voltage | Depend on the batter type | Charge current | 35A | 20A | 65A | 35A | 75A | 45A | 30A | 35A | 35A | 35A | 40A | 75A | 50A | Charging the inverter for intelligent charging; , The size of the charge current is determined by the: The regulation of the inverter\Capacity of the battery at\battery voltage | Charge current correction | ± 5A | Initial Charge Voltage | Normal batteryvoltage 9.0 ~ 15.7V / 18.0 ~ 31.4V / 36.0 ~ 62.8V | Charger short-circuit protection | Circuit Breaker | Circuit breaker | 10A | 20A | 30A | 40A | Over voltage protection | When the battery voltage > 15.7Vdc/31.4Vdc/62.8Vdc, every second sounds 0.5 second, it breaks down after 60 seconds. | | model | Net weight (KG) | gross weight (KG) | product size (L*W*H)MM | package size (L*W*H)MM | | | 1KW | 12 | 13 | 358*188*168 | 480*330*285 | | | 1.5KW | 18 | 19.2 | 425*188*168 | 535*330*285 | | | 2KW | 19.5 | 20.9 | 425*188*168 | 535*330*285 | | | 3KW | 24 | 25.4 | 425*188*168 | 535*330*285 | | | 4KW | 36 | 37.5 | 622*188*168 | 730*330*285 | | | 5KW | 41 | 43 | 622*188*168 | 730*330*285 | | | 6KW | 44 | 46 | 622*188*168 | 730*330*285 | | | For reference only, if there is a change without notice | | | | | | | | | | | | | | | | | | | | | | If you want to purchase this product, Please make sure the following parameters. |
Power rating | | 1KW, 1.5KW, 2KW, 3KW, 4KW, 5KW, 6KW |
DC volts | | DC12V & DC24V & DC48V & DC36V |
AC volts | | AC110V & AC220V & AC100V & AC120V & AC230V & AC240V |
Frequency | | 50HZ & 60HZ |
The UPS function | | YES & NO |
The use of occasions | | Solar & Wind & Car & Family expenses & Industrial use & other |
AC priority use & DC priority use | | AC priority use & DC priority use |
If DC priority use | | There are two kinds of programming: 1, every time itstarts, After the batteris is full, and then converted to DC supply. 2, After the batteris is 13.5V/27V/54V, and then converted to DC supply. |
AC charging function | | YES & NO |
Trade Terms | | EXW, FOB, FCA, FAS, CIF, CFR, DEQ, and so on |
Other description | |
| | | | | | | |