DC12V to AC 220V 50HZ 500W Pure Sine Wave Power Inverter |
Power Specifications | 300W~12KW |
DC Input Specifications |
Rated Voltage Specifications | DC12/24/48/72V-AC220V | DC12/24/48/72V-AC110V |
Operating Voltage Range(Normal Operating Battery Voltage) | 10V-16V (DC12V Power Supply) 20V-32V (DC24V Power Supply) 40V-64V (DC48V Power Supply) 60V-96V (DC72V Power Supply) |
Low Voltage Alarm(beep alarm to alert users when battery's voltage is too low) | 10.5Vdc ± 0.3Vdc (12V Power Supply) 21.0Vdc ± 0.6Vdc (24V Power Supply) 42.0Vdc ± 1.2Vdc (48V Power Supply) 63.0vdc ± 1.8Vdc (72V Power Supply) |
Low Voltage Shut off (shut off when battery's voltage is too low) | 10.0Vdc ± 0.3Vdc (12V Power Supply) 20.0Vdc ± 0.6Vdc (24V Power Supply) 40.0Vdc ± 1.2Vdc (48V Power Supply) 60.0Vdc ± 1.8Vdc (72V Power Supply) |
Low Voltage Recovery (Automatic Boot when battery's voltage returns to normal) | 12.0Vdc ± 0.3Vdc (12V Power Supply) 24.0Vdc ± 0.3Vdc (24V Power Supply) 48.0Vdc ± 0.3Vdc (48V Power Supply) 72.0Vdc ± 0.3Vdc (72V Power Supply) |
High Voltage Alarm and shut off (beep alarms and shut off when the battery's voltage is over high) | 16Vdc ± 0.3Vdc (12V Power Supply) 32Vdc ± 0.6Vdc (24V Power Supply) 64Vdc ± 1.2Vdc (48V Power Supply) 96Vdc ± 1.8Vdc (72V Power Supply) |
High Voltage Recovery (Automatic boot when battery's voltage returns to normal) | 15.5Vdc ± 0.3Vdc (12V Power Supply) 31.0Vdc ± 0.6Vdc (24V Power Supply) 62.0Vdc ± 1.2Vdc (48V Power Supply) 93.0Vdc ± 1.8Vdc (72V Power Supply) |
Inverter Efficiency | ≥90% |
DC-priority type, battery low voltage conversion point when there is utility electricity ( turn to utility electricity to supply when battery voltage is lower than these) | 11Vdc ± 0.3Vdc (12V Power Supply) 22Vdc ± 0.6Vdc (24V Power Supply) 44Vdc ± 1.2Vdc (48V Power Supply) 66Vdc ± 1.8Vdc (72V Power Supply) |
DC-priority type, battery low voltage recovery point after turning to utility electricity to supply, (turn to battery to supply electricity when the battery's voltage is higher than these) | 13.5Vdc ± 0.3Vdc (12V Power Supply) 27.0Vdc ± 0.6Vdc (24V Power Supply) 54.0Vdc ± 1.2Vdc (48V Power Supply) 81.0Vdc ± 1.8Vdc (72V Power Supply) |
AC Input Specifications |
Rated Voltage Specifications | 220VAC System | 110VAC System |
Input Voltage Waveform | Pure Sine wave (utility electricity or generator) | Pure Sine wave (utility electricity or generator) |
Rated Input Voltage | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac |
Low Voltage Shut off | 180Vac±4% | 85Vac±4% |
Low Voltage Recovery | 195Vac ±4% | 90Vac ±4% |
High Voltage Shut off | 260Vac±4% | 135Vac±4% |
High Voltage Recovery | 255Vac±4% | 130Vac±4% |
Charging rules of Utility Electricity | Three Stages: |
Constant current charging (constant current stage)→constant voltage(constant voltage stage)→float (constant voltage stage) |
Utility Electricity Supply Efficiency | ≥98% |
Conversion Time (AC to DC) | <4ms |
Conversion Time (DC to AC) | <8ms |
AC output specifications |
Rated output voltage (V) | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac |
OutputVoltage Range | ±10% rms |
Rated output frequency(Hz) | 50Hz ± 0.3Hz/60Hz ± 0.3Hz(selectable) |
Power Factor | 1.0 |
Output Wave form | Pure sine wave |
Waveform distortion rate( THD ) | ≤3% ( Linear load ) |
Dynamic Response( 0~100% ) | 5% |
Peak Factor ( CF ) | 3:1 |
Overload Protection (SMPS load) | (110%<Load<125%) ±10% :disconnecting the output voltage after 15 minutes (125%<Load<150%) ±10% :disconnecting the output voltage after 1 minute (Load>150%) ±10% :disconnecting the output voltage after 20 seconds |
Other notes |
Continuous operation time | Can Continuous operation |
Comsuption when Normal Boot ,no-load | ≤Rated Power×2.5% |
Comsuption of energy-saving mode | ≤6W |
Safety Certification | CE(EN62040-1) EMC :EN62040-2, C2 |
Communication Interface | RS232 / (Customizable) |
Cooling | Temperature-controlled variable speed cooling-fan (Ventilation condition) |
Noise( dB\1 meter ) | <60dB |
operate temperature ( ºC) | -10~+45 |
Storage Temperature( ºC) | -20~+55 |
Using Environment Humidity | 0-95% relative humidity(No condensation) |
Altitude( m ) | ≤5000( More than 1000 m, derating ) |
Display Way | LED lights +LCD screen |
Alarm Way | Buzzer sounds alarm |
Protection Functions | Low voltage protection, high voltage protection, high temperature protection, short circuit protection, leakage protection, overcurrent protection, overload protection, low voltage recovery, high voltage recovery, intelligent temperature control, solid barrier alarm |
Protection Level | IP20 / Customizable |
Parameter Specifications of Solar Charge Controller |
Specifications | 12V/10A | 12V/20A | 12V/30A | 12V/40A | 12V/50A | 12V/80A | 12V/100A |
Rated Power (W) | 120 | 240 | 360 | 480 | 600 | 960 | 1200 |
Rated Charging Current(A) | 10 | 20 | 30 | 40 | 50 | 80 | 100 |
Rated DC Voltage (V) | 12 |
PV Highest Voltage(V) | <25 |
PV Maximum Power (W) | 120 | 240 | 360 | 480 | 600 | 480×2 ways | 600×2 ways |
Battery Overcharge Protection Voltage(V) | 14.3 |
Battery Overcharge Recovery Voltage(V) | 13.7 |
Battery Constant Voltage charging Voltage(V) | 13.5 |
Battery Over-discharging alarm Voltage(V) | 10 |
Protection Function | Night: anti-reverse charging, solar reversed |
Control Mode | PWM or MPPT |
Other Notes | Please refer to solar controller manual |
Specifications | 24V/10A | 24V/20A | 24V/30A | 24V/40A | 24V/50A | 24V/60A | 24V/100A |
Rated Power(W) | 240 | 480 | 720 | 960 | 1200 | 1440 | 2400 |
Rated Charging Current(A) | 10 | 20 | 30 | 40 | 50 | 60 | 100 |
Rated DC Voltage(V) | 24 |
PV Highest Voltage(V) | <50 |
PV Maximum Power (W) | 240 | 480 | 720 | 960 | 1200 | 1440 | 1200×2 ways |
Battery Overcharge Protection Voltage(V) | 28.6 |
Battery Overcharge Recovery Voltage(V) | 27.4 |
Battery Constant Voltage charging Voltage(V) | 27.0 |
Battery Over-discharging alarm Voltage(V) | 20 |
Protection Function | Night: anti-reverse charging, solar reversed |
Control Mode | PWM or MPPT |
Other Notes | Please refer to solar controller manual |
Specifications | 48V/20A | 48V/30A | 48V/40A | 48V/50A | 48V/60A | 48V/80A | 48V/100A |
Rated Power(W) | 960 | 1440 | 1920 | 2400 | 2880 | 3840 | 4800 |
Rated Charging Current(A) | 20 | 30 | 40 | 50 | 60 | 80 | 100 |
Rated DC Voltage(V) | 48 |
PV Highest Voltage(V) | <100 |
PV Maximum Power (W) | 960 | 1440 | 1920 | 2400 | 1440×2 ways | 1920×2 ways | 2400×2 ways |
Battery Overcharge Protection Voltage(V) | 28.657.2 |
Battery Overcharge Recovery Voltage(V) | 54.8 |
Battery Constant Voltage charging Voltage(V) | 54.0 |
Battery Over-discharging alarm Voltage(V) | 40 |
Protection Function | Night: anti-reverse charging, solar reversed |
Control Mode | PWM or MPPT |
Other Notes | Please refer to solar controller manual |